Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • j5
  • j5 Tech Notes

TN 1271 Using Cascading Style Sheets in j5

Last updated: March 13th, 2026

Description

  • Author: Ron Tanner
  • Published: March 13th, 2026

Details:

Description

This article from InSource shows how to leverage Cascading Style Sheets in j5

  • Author: Ron Tanner
  • Published: 06/27/2022
  • Applies to: j5 2019

Details

Using Cascading Style Sheets in j5

Cascading Style Sheets (CSS files)can be added in different locations to affect different levels of a j5 system. The location determines where the rules will be applied in the system. 

To apply a CSS to all field labels the entire j5 site to a particular color you would add a site.css file to the project root. The contents would be as follows: 

Label { 

color:#ff9900; 

} 

With the use of CSS classes in the site.css file you can apply CSS more specifically. 

Specific selectors will override general selectors.

Example: 

  • A selector at the module level will be more specific than a matching one at a site level
  • A selector with a CSS class component (example: Label.important) will be more specific than one without (example: Label) 

Example: adding a module.css file to the Organization module. 

 Field { 

 background-color:#00FF00; 

color:#ff9900; 

} 

Label { 

 background-color:#a0a0a0; 

color:#4F4F4F; 

} 

The result of the logbooks in this module: 

Adding a CSS file to the logbook (logbook.css) should be located at the same level as the logbook.yml file.

Example: 

Adding the tag to the specific field(s):

 Adding the logbook.css file at the same level as the logbook.yml file: 

The logbook.css file: 

Label.asset_type { 

 background-color:#FF0000; 

 font-weight: bold; 

} 

Result: 

You can also add colors to field options: 

There is an option to apply colors to the field options in the logbook list view (grid view).

Example: colors can be added to a select type field and this will then be applied and displayed in the grid view. 

 

styling j5
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More

How to receive group emails

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand