TN DR103 Generate Excel files from Dream Report instead of PDF

Last updated: February 28th, 2025

Description

  • Author: Brian Schneider
  • Published: February 28th, 2025

Details:

Description

This article from InSource shows how to generate an Excel file from a Dream Report project report.

  • Author: Dillon Perera
  • Published: 03/06/2017
  • Applies to: Dream Report

Details

When developing reports in Dream Report the default format for output is to a PDF file. Occasionally there is a need to generate this same data to an Excel file so that additional manipulation can be done.

When converting to Excel format, be aware that not all objects in a Dream Report file can be converted, because PDFs are capable of showing additional content such as Graphics, which will not be directly relevant in an Excel spreadsheet. Objects that can be exported are:

  • Single Data Objects
  • Compound Objects
  • Expression Objects
  • Item Tables
  • Alarm Tables
  • Step Tables
  • SQL Tables

To use Excel files, we need to specify which objects will be exported, and where on the Excel Sheet they will be displayed.

  1. Ensure all objects which should be displayed in Excel have been given a name. We will need this information to position the objects on the Excel sheet.

    If you do not want to actually display the object name in PDFs, etc., you can uncheck this option once completed, but you will need to enable the option to allow you to enter a name in the field.
  2. In the List of Repoorts, right click and go to Report Settings. Select the Report File Format section, and put a checkmark in the Excel option.
  3. Click on the Settings button.
  4. Use the wizard to position the Data and Table Objects that you've defined, and drag them onto the Excel template to specify where they should be displayed.
  5. Save your settings.
  6. Generate the report to see the result.
excel generation report export
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand