TN MES108 Example API Call to Add Inventory in Wonderware MES
Last updated: March 11th, 2025Description
- Author: Brian Schneider
- Published: March 11th, 2025
Details:
Description
This article from InSource Provides example script using Stateless API call to add inventory in Wonderware MES.
- Author: Michael Walker
- Published: 09/25/2015
- Applies to: Wonderware MES 2014
Details
Below is an example script calling the aaStorageExec.AddInv method in the stateless API. Note that the Me.<Attributes> relative references need to be configured within the Application Server object for this example to function properly.
dim Result as aaMES.Result;
dim rowID as integer;
dim DT as aaMES.aaDBDateTime;
dim lotNo as aaMES.aaDBString;
dim testlotNo as String;
testLotNo=me.lotNo;
lotNo= new aaMES.aaDBString(testlotNo);
Result= aaMES.EnProd.aaStorageExec.AddInv(me.sessionId,me.entityName,"",me.itemId,"GoodGrade","GoodState",me.GoodQty,lotNo,Null,Null,Null,DT,Null,Null,Null,Null,Null,Null,Null,Null,Null,Null,Null,Null,Null,Null,Null,rowId);
If Result.Success then
me.ResultText="successfully Added Inventory to entity: "+me.EntityName+". And received RowID: "+rowID;
else
me.resultText="Add Inventory Failed: "+result.Exception.Message;
endif;