Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Application Server
  • AVEVA Application Server Tech Notes

TN 1330 XPS Documents not Displaying Properly in Windows 11

Last updated: March 6th, 2025

Description

  • Author: Rich Brooks
  • Published: March 6th, 2025

Details:

Description

This article from InSource shows a workaround for XPS Documents that do not display properly in Windows 11 during the install of AVEVA Application Server.

  • Author: Rich Brooks
  • Published: 2/21/2023
  • Applies to: Application Server 2020R2 SP1 and higher

The installation of AVEVA System Platform stops on the End-User License Agreement (EULA) acceptance prompt. 

You are unable to accept and agree to advance to the next step of the installation. This is the result of applying various Microsoft Updates. Microsoft has provided KB5022083 as a workaround to this issue. A PowerShell script needs to be run to apply the fix but may be blocked. The following steps describe running the PowerShell script from Windows 11.

Start by downloading KB5022083 from the following link: PowerShell script

Next, run Windows PowerShell ISE as an administrator. Run the script using the following command: .\kb5022083-compat.ps1 -install

You will likely see an error stating scripts are disabled on the system. The Execution Policies are blocking the script.

Type in the following command to see the current Execution Policies: Get-ExecutionPolicy -list

Temporarily modify the policy by running the follow command: Set-Execution Policy Unrestricted

Viewing the Execution Policy list again shows the Local Machine is set to Unrestricted.

You may now run the PowerShell script with no error.

Be sure to run the following command to set the Excecution Policy back to Undefined using the following command: Set-ExecutionPolicy Undefined

You may now resume the installation for AVEVA System Platform. The EULA document will be displayed as expected.

xps files windows 11
Give feedback about this article

Recommended articles

TN 1307 How to Reset Security System in an Intouch Machine Edition or Edge application

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand