[ISS Support Case] Dream Reports Email Reports is Intermittent

Last updated: October 17th, 2025

Description

Dream Reports server has had some intermittent issues with emailing reports that were previously scheduled. Nothing has changed with the system recently. Have two reports which run on a time based schedule and either write results to Excel or a PDF as a shared file on a file server. Two things happened Mill had a maintenance outage not a full shut down. Equipment went from running state to stopped state. Historian kept running, they still collect environmental data but emails stopped working. When the equipment was placed in a running emails started working again. In the mean time discovered issues with the way they reports are administered due to windows limitations. When the report is supposed to generate an email, in the logger MakeLogonFileServer1 failed with error 1326: The user name or password is incorrect. Login = HEW\CV_DR MakeLogonFileServer2 failed with error 1219: Multiple connections to a server or shared resource by the same user, using more than one user name, are not allowed. Disconnect all previous connections to the server or shared resource and try again. System will generate a report manually. The server was rebooted multiple times with no change in behavior then seemingly for no reason email started working briefly before stopping again. Not an issue with the mail server.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Aveva Reports for Operations
Version: 5.0
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 08/08/2022
Case: 82206
Give feedback about this article

Recommended articles

[ISS Support Case] Dream Reports issue with query

Currently have a sql that works in a table. They want to use that query in an advanced OBDC driver. They create the driver using custom view, the columns populate as selected. All they get are the values for A. They had null values but that has been fixed but they need help debugging.

Read More

[ISS Support Case] Reports for Operations, Compatibility (?)

-Reports for Operations. -Has runtime management console. -When running report, automatically, no values. -Has to Restart the management console, manually run the reports, then there is information. -Customer is on 23H2 Build (2261.3737) , Compatibility Matrix only shows Windows 11 22H2 SAC Professional x64 as compatible. -He will need to consult with the security team, to see if they can go back to a 22H2 build. Overnight Reports are being generated as N\a. Something about the manager being left on for long periods. Yesterday I changed the generation time to soon after configuring it, and it generated fine, and if I click on generate manually it generate manually it's fine. But when I wait several hours for the report to generate after midnight it will push a report that is all N/A, except the 24th row which will have data. To fix it I have to restart the manager, then it starts generating correctly again.

Read More

[ISS Support Case] How To Move & Upgrade A Dream Reports Project

Question I have InTouch HMI ODS reports. Bought a new license brought intouch application over (no issues). Not much experience with Dream Reports. Copied project folder over, is that it? What do I need to do to get this running? DR 4.7.0 -> ARFO2023 R2

Read More

[ISS Support Case] Aveva Reports for Operations Upgrade

SI wants to know if base download contains FactoryTalk drivers for communication to Rockwell's products. Also had general project upgrade questions. Found Factorytalk SDK no longer included in 2023R2.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand