Details:

Using the checkout utility.

  1. Open command prompt as an Administrator.
  2. Type the path where the Checkout Utility is available. (C:\Program Files (x86)\Common Files\ArchestrA\Licensing Framework\License API2.)

    3. Type AELicCheckout.exe with the following 

  • The path where the utility is available
  • The operation you want to perform
  • The part number

     4.  For example, if the utility is available in the path C:\Program Files (x86)\Common        Files\ArchestrA\Licensing Framework\License API2, and you want to check out the part number INTR60K17, then type the following: C:\Program Files (x86)\Common Files\ArchestrA\Licensing Framework\License API2 AELicCheckout.exe checkout -pn “INTR60K17”

     5. Press Enter.

  • The checked-out licenses are displayed on the Reservations grid of the License Manager, with details such as Serial Number, Product Name, Component Name, Version, and Count.

Note: The licenses get checked out through the primary server. Therefore, if you are using a redundant pair, the primary server is required to be available during the checkout operation.

utility license checkout
Give feedback about this article

Recommended articles

[ISS Support Case] License Release Request

Client reached out due to previous license server failing. User is now unable to activate license on new license server.

Read More

[ISS Support Case] License Release Request

Client reached out to request release of license.

Read More

[ISS Support Case] License Release Request

Client reached out as they were unable to activate a license and they were receiving an error message stating the activation ID is already in use.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand