TN - LM - 25042417 How to drop checked out licenses.

Last updated: May 18th, 2026

Description

  • Author: Chris Cleope
  • Published: May 18th, 2026

Details:

Description  

This tech note describes using the checkout utility.

Solution Steps:                         

 

  1. Open command prompt as an Administrator.
  2. Type the path where the Checkout Utility is available. (C:\Program Files (x86)\Common Files\ArchestrA\Licensing Framework\License API2.)

    3. Type AELicCheckout.exe with the following 

  • The path where the utility is available
  • The operation you want to perform
  • The part number

     4.  For example, if the utility is available in the path C:\Program Files (x86)\Common        Files\ArchestrA\Licensing Framework\License API2, and you want to check out the part number INTR60K17, then type the following: C:\Program Files (x86)\Common Files\ArchestrA\Licensing Framework\License API2 AELicCheckout.exe checkout -pn “INTR60K17”

     5. Press Enter.

  • The checked-out licenses are displayed on the Reservations grid of the License Manager, with details such as Serial Number, Product Name, Component Name, Version, and Count.

Note: The licenses get checked out through the primary server. Therefore, if you are using a redundant pair, the primary server is required to be available during the checkout operation.

utility license checkout
Give feedback about this article

Recommended articles

[ISS Support Case] IDE License Acquisition Failure

Client reached out as when user was attempting to launch the IDE they were receiving a license acquisition failure message.

Read More

[ISS Support Case] InTouch License Acquisition Failure

Client reached out due to receiving failure to acquire license when attempting to start WindowViewer.

Read More

[ISS Support Case] InTouch License Acquisition Failure

Client reached out as when user was attempting to start InTouch they were receiving a license acquisition failure message.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand