TN - 1495 Viewing Real-time InTouch Data from XLReporter

Last updated: November 10th, 2025

Description

  • Author: Rich Brooks
  • Published: November 10th, 2025

Details:

Description

This article from InSource shows how to view real-time InTouch data from XLReporter.

  • Author: Rich Brooks
  • Published: 11/7/2025
  • Applies to: AVEVA InTouch HMI 2023R2 SP1 and higher

Details

It is recommended to replace the legacy native InTouch real-time data connector when upgrading to SmartSights XLReporter 16.2 or higher.  The Aveva Gateway OI Server is the best option to replace the direct connection that was used previously.  Typically, InTouch HMI is upgraded at the same time to Aveva 2023R2SP1 or higher.

Start by clicking on the Connectors button from the XLReporter Project Explorer.

Next, delete the existing InTouch direct access connector.  Click on the Add button.  Expand out AVEVA folder to select OI Gateway Real-time values and click on the OK button.  Use the same name as previously (InTouchDA in this example) for the Connector Name.  Click on the Test Connection button and then click on the OK button to save the change.

 

The next step is to configure the Gateway OI Server.  Open the Operations Control Management Console (OCMC).  Right-click on OI.Gateway.3 to select InTouch Connection.  Enter the path to the InTouch project on the local machine and then click on the Tag Browser button.

Highlight to select all of the required tags from the InTouch project.  Click on OK to added the selected tags to the Device Items.  Click on the save icon in the upper right of the screen.

Next, each of the reports will need to be updated for OPC.  Double-click on the first report template from the Project Explorer.  

Click on the Connect button to edit the connections.  Select each of the InTouchDA items one at the time and click on the Modify button.

Start by click on the ellipse button to open the Tag Browser.  Expand out Online to select Tagname.  Select the required item from the OPC server.  A filter may be used to narrow down the tag list.  Next, click on the right error to move the tag into the Selected Items.  Click on the two OK buttons to return back to the Data Connect screen.  

 

Select the next InTouchDA item in the list and click on the Modify button. Repeat the steps for each InTouchDA item. 

unnamed piece nameless entry
Give feedback about this article

Recommended articles

[ISS Support Case] Question about Galaxy Communication object

Every time I restart Gateway driver after some changes Device Group are empty until I redeploy Communication Object in System Platform. Is it standard behavior for this driver? I assume after restart of the UKPETAPP026 machine the driver will not collect data as long as Communication Object is not redeployed? I set Topics to Active All Scan Mode.

Read More

[ISS Support Case] Display InTouch Tags In Dream Report As a Widget

Working with Dream Reports more familiar with InTouch. Is it possible to import screens from InTouch to Dream Reports? objective: create a 'dashboard' with widgets and make tables like a flow chart like a hybrid between DR and InTouch. Possible to have a widget that updates at a defined interval? Data Source: InTouch Tag: Live Analog Value Dynamically Update?

Read More

[ISS Support Case] Remote Response Object Error

RRO Derived Templates for their Notifier and Communicator WILL NOT OPEN THE EDITOR in the IDE. When you click on them, they quickly check out and then check back in without opening the editor(s). The following errors are generated below. The instances of these derived templates however WILL DEPLOY and WORKS WELL IN RUNTIME. This only started to occur when they upgraded to SP1 of 2020 R2

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2025 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand