TN IT215 Preventing Return To Normal (RTN) events from displaying in a view Type Application

Last updated: March 19th, 2025

Description

  • Author: Brian Schneider
  • Published: March 19th, 2025

Details:

This article from InSource shows...

  • Author: Peter Farrell
  • Published: 03/30/2016
  • Applies to: InTouch 10.x and above

Details

When an InTouch application is configured as a View type application, it is not possible to use he InTouch based alarm configuration options to limit the alarm display to only active unacknowledged, and prevent Return To Normal status event from being published in the alarm display.

As can be seen in the screen shot below of the popup that appears when you configure the application to be a “view” type application, it is advised that, “Also note that no historical logging or alarming is done within InTouchView. However, an InTouchView can be used to display alarms generated by objects in the "Galaxy", i.e. in the Application Engine.”

However, since with a View type application all alarms are Galaxy based, it is possible to limit the display by using the ArchestrA dot net control alarm display and implementing a query filter and setting the state to “All ALM Records” only.

With the ArchestrA Graphic symbol hosting the Dot Net Alarm Display, double click on the display to open it’s properties. You can now build a new query filter.

Note that unless the Alarm Mode is configured for Historical mode, you will have to add criteria for "Group" and "Provider or cancel this operation and change the mode to Historical Alarm mode before creating the query. Attempts to save your query without these criteria will warn you to do so with the following popup.

Once you have created your query filter, you can reference the filter by name at the end of your alarm query separated by another exclamation mark:

\Provider!Area!Filter

\\Node\Provider!Area!Filter

avoid rtn events exclude rtn
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand