[ISS Support Case] SelectRecipe & RecipeLoad Script Functionality Issue

Last updated: March 7th, 2025

Description

Client reached out as he upgraded from InTouch 2011 to InTouch 2020 R2 Sp1 and previously when executing the aforementioned scripts it would initialize a view which showed the recipe select menu allowing the user to initiate different recipes. After migrating to 2020 R2 SP1 when using the script the cells are truncated and the user can only view the first three characters.

  • Author: Kevin Modlin
  • Published: March 7th, 2025

Details:

Product: InTouch
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 08/22/2024
Case: 87662
recipe pick recipe selection
Give feedback about this article

Recommended articles

[ISS Support Case] How To Use wwClient To Validate IO

Now running just a regular window in WV Configured PLC's / communication drivers. Not getting data. ??Tested with wwClient - No (unfamiliar process)

Read More

[ISS Support Case] How to Automatically Start InTouch on Windows 10

Client reached out looking for guidance on automatically starting InTouch on node startup.

Read More

[ISS Support Case] Unable to access Intouch applications

Getting an error stating wm.exe cannot be found when trying via application manager. Try via IDE, gets popup application was developed in Edge, do you want to convert? If Yes, loops to same cannot find wm.exe error. SI not on support, contacted AM

Read More

[ISS Support Case] Complex Graphic Upgrade Results In SUSPEND Suitelink Updates

I have a complex InTouch graphic that I have been using for many years on version 2012R2 without a problem.. I have been recently upgrading my graphics to version 2020, but this one particular graphic is causing SuiteLink to suspend updates for several seconds (minutes), then resuming for a few seconds, and going back to Suspend. I tried changing the update rate on these many points to 30000ms, but it still gave me the same problem.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand