[ISS Support Case] Seeking Information on Running ALARMDB Logger as a service

Last updated: October 17th, 2025

Description

Client is seeking assistance running AlarmDB Logger as a service. Alarms are not showing up when running as a service. When running the Alarm Logger as a service, I can view all past alarms in the database but it wont log any new alarms. Only when I run it as an application will it log new alarms. Again it shows connected to the database in either mode, but will only log NEW alarms when its running as an application. To answer the questions below: 1. The connection shows succeeded when testing it in the DB Manager. 2. The Wonderware Alarm Logger Services is Running. 3. The alarm query is \InTouch!$System. 4. The AlarmDBViewCntrl shows connected.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: InTouch
Version: 2023 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 05/07/2025
Case: 89131
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand