[ISS Support Case] PLC to OI Server Communication Failure

Last updated: March 6th, 2025

Description

Client called in due to HMI screen showing blank which was connected to a specific PLC. The Server tree had 20+ PLC's listed under it and two of them seemed to not be sending data to Intouch. Confirmed this through test with WWClient $Sys$Status tag and some of the analog tags from the PLC's. The test were passed on all but two PLC's. Suggested to client to deactivate and reactivate OI server, but some of the connected PLC's are in live environments. Client advised they may need to migrate these PLC's back to the older servers in order to perform a server restart/repair.

  • Author: Kevin Modlin
  • Published: March 6th, 2025

Details:

Product: InTouch
Version: 2020 R3
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 01/23/2024
Case: 86106
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand