Client is adding a new MBTCP data source, a SEL 3530 RealTime Automation Controller to use with InTouch 2020 R2 SP1. Client is experiencing an issue with the data values in the OI Server and InTouch are slightly different than the actual values coming from the PLC. Client has tested this from another HMI and the data is correct. Another issue the client has noticed is out of 50 analog values, 47 of them are showing as a real with a decimal, 3 of them are showing as a integer, even though all the tags were created with the same data types in InTouch and the source has created them all as 32 bit floating.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: InTouch
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 06/18/2025
Case: 98248
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand