Customer reported that client nodes were unable to acquire a valid read/write license. The error displayed was: "Unable to find or acquire a read/write license." Upon investigation via a support call, it was determined that the environment included mixed software versions: a 2014 R2 Galaxy and two client machines running 2020 R2. The client nodes were configured to pull licenses locally, as confirmed through the AVEVA Configurator. Further investigation revealed the license was managed through a redundant license server pair. When attempting to launch the AVEVA Enterprise License Manager to inspect the license availability, the following error occurred: "Access to the License Manager is denied." This was attributed to a permissions issuethe currently logged-in user was not a member of the AVEVA Enterprise License Manager Users group. When attempting to manually add the user to the group via Local Users and Groups, the system returned another permissions error, indicating that administrative rights were insufficient to apply the changes.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: InTouch
Version: 11.1
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 07/25/2025
Case: 98613
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2025 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand