[ISS Support Case] Issue with InTouch connection to ABCIP

Last updated: October 17th, 2025

Description

When the operators initially launch the application, the IO connects with no problem. The application will run with no issue. After an undetermined amount of time, the OI Server disconnects and cannot be re-established without restarting the application. The random disconnection, even after the tag DB has been persisted makes no sense to me. Here are a couple of interesting notes--- If I run another instance of the application on the same server, the IO will connect, even while the production PC will not. Also I have other CompactLogix L32E v16.2 PLCs that run flawlessly, but they are NOT deployed, and the OI version is the G-2.0 v7.0.0 (not sure if this makes a difference) This seems to occur every time they user walks away from the HMI for a while and then returns.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: InTouch
Version: 2017
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 09/29/2022
Case: 82587
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand