[ISS Support Case] HMI Communication Loss

Last updated: March 7th, 2025

Description

Client reached out due to two of several HMI nodes loosing communication intermittently. When reviewing the logs I observed several instances of Suitelink suspend and resume messages. This indicates an overload condition generally. SuiteLink handles the possible over-flooding of its write buffer in the above condition by posting a message to itself every one hundred milli-second by default. This message estimates the depth of the message queue. If the message queue is too deep then SuiteLink generates SUSPEND events message on all connected clients and servers. When the message queue falls to a minimum depth, SuiteLink sends a Resume event message to its clients and servers. If a PC or network gets busy for any reason and can not handle the suitelink traffic, a suspend event will occur and suitelink is supposed to stop sending data until it receives a resume event.

  • Author: Kevin Modlin
  • Published: March 7th, 2025

Details:

Product: InTouch
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 01/08/2025
Case: 88531
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand