Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA InTouch
  • AVEVA InTouch Support Cases

[ISS Support Case] Editing an ActiveX script 'invalid reference or unknown OCX method

Last updated: October 17th, 2025

Description

Direct email: click and newstart scripts contain hostname references. However, when I attempt to save a change in either of these scripts from hostname to IP address, I get the error Invalid reference or unknown OCX Method: Are the lines that begin with # comments? If so, this code would appear as if it is not even used. If the hashtags are not comments, I did find TN IT242 Considerations when Migrating InTouch applications to another PC - InSource Solutions (insourcess.com), but I could not determine that any of those factors applied. Do you know what I might need to do to complete the change of hostname to IP address in the ActiveX scripts?

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: InTouch
Version: 11.6
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 12/29/2022
Case: 83337
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand