[ISS Support Case] Configuring SIDIRECT Communication With Intouch 2023

Last updated: March 6th, 2025

Description

We are setting up connections to Siemens S7-1500 PLCs and those are new to me in AVEVA world. I am looking for some basic information on OI Server setup using SIDIRECT and corresponding access setup in InTouch. We plan on using the Legacy reference. I have found the required settings for PLC communication and I will confirm those settings with the vendor. There will be five independent S7-1500 and I will be creating five different Legacy objects. Is the Legacy object name the Topic name assigned in InTouch or is it the Device Group name in the Legacy object. And what is the application name to use for InTouch. And I wasn't sure if I needed to define the tags in the Legacy object. I am used to AB where that is not needed. I have the AVEVA doc link, https://docs.aveva.com/bundle/sp-cdp-drivers/page/SIDIR4OI4index.html, for SIDIRECT. Any other documents that have the complete steps to setup the OI server and then the InTouch settings would be helpful.

  • Author: Kevin Modlin
  • Published: March 6th, 2025

Details:

Product: InTouch
Version: 2023
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 12/12/2024
Case: 88419
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand