First and second attempt at script execution within an indirect tag fails, but the third execution works properly existing system (yes)? new work being done not working as expected. Modern application Action Script for a button (in AG) looks at an array of 20 objects Call notes: Wrote LogMessage in the loop which we see in the log however not all of the elements are being written as expected. Index zero seems to be skipped as do some of the expected tag values at the end of the resultant string.

  • Author: Kevin Modlin
  • Published: March 7th, 2025

Details:

Product: InTouch
Version: 2017
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 01/17/2023
Case: 83423
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand