[ISS Support Case] Backup Server setting not saving

Last updated: March 7th, 2025

Description

1/30/2023: -License Server, 3 Clients. -Primary and backup license server but, no backup license server. -Old configuration keeps going back to backup. -Happens Every couple days. -Goes into each client individually, But keeps defaulting back to old setup. -All licenses are on one server. 2/9/2023: -Left VM with Receptionist. ----2/10/2023: Team's Meeting 1:30P.M ---2/15/2023: Team's meeting at 10:00 A.M 2/15/2023: -During meeting, we removed the "Backup license server" that had no activated license(s) on it. It served no purpose. Went through log files. Nothing obvious. -Made port '55555' open for Inbound and Outbound rule for the port exemptions. -Checked other firewall settings. -Have to wait to see if the "Enable backup" checks itself in and loses the license from the primary, to determine if this is resolved. 2/20/2023: -Disabled Reservation for 60k Runtime and historian Client. 2/28/2023: -Team's meeting. -Put demo license on all 3 Client servers. -Deactivated License(s) on primary server. -made a backup of LicenseManagerData.db. -Deleted, then copied new blank .db. -restarted machine after activating the licenses. -Client's grabbing license as normal. -Awaiting any faults, yet to be seen. 3/2/2023: -Error occurred again. 3/14/2023: -Team's meeting; Cleaned up backup license database through registry. Found that PrimaryScada was written in for a backup through the registry. -Also attempted to Upgrade LM.

  • Author: Kevin Modlin
  • Published: March 7th, 2025

Details:

Product: InTouch
Version: 2020
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 03/23/2023
Case: 83623
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand