Client reached out as when user is attempting to connect to the WWALM DB the user is receiving a "Connection to Server not available" error message. Troubleshooting steps taken so far: Enable mixed mode in SQL Enable the SQL SA account Tested connection to DB with a UDL file and it was successful. Make sure SQL port 1433 is not blocked and is open on that machine. In the SQl Server Configuration manager: TCP/IP should be enabled? In the SQl Server Configuration manager: Names Pipes should be enabled? In SSMS>Security>Logins: Windows user and SA user should have DB_Owner permissions to the WWALMDB (This would fail with the error message SA Lockout Err 15405 Cannot use special principal SA)

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: InTouch
Version: 2020
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 03/12/2025
Case: 88794
Give feedback about this article

Recommended articles

[ISS Support Case] AVEVA Map OMI App

Client reached out due to when opening ViewApp with embedded OMI MapApp user was receiving the following error: "Page load failed. The browser encountered a connection error while trying to load http://localhost:55601/Map/map-runtime.html. Try again later."

Read More

[ISS Support Case] WSP 2023 Installer Hangs When Applying P02

Fresh Install Applying P02 - reloaded workstation OS - installed 2023 (no issue) - Install hung on Application Server DOC install - FROZE - Killed task - Uninstalled Manually - Reinstalled gets hung at the same spot some

Read More

[ISS Support Case] InTouch issue

Upgraded from 2020 to 2023. Now getting a message from within remote desktop session that says could not acquire a ReadWrite license.

Read More

[ISS Support Case] mismatch occurred error with archestra industrial graphic

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand