TN IT224 How to bypass the opening screen in Secure Gateway with InTouch Access Anywhere

Last updated: February 20th, 2025

Description

  • Author: Glenn Yancey
  • Published: February 20th, 2025

Details:

Description

This article from InSource shows how you can bypass the opening screen in Secure Gateway. This is so that you don't have to constantly reenter the name of your InTouch Access Anywhere Server that the Gateway is funneling you towards.

  • Author: Glenn Yancey
  • Published: 08/31/2016
  • Applies to: InTouch Access Anywhere (2012 R2 and Higher)

Details

The role of the Secured Gateway is to funnel external users of InTouch Access Anywhere to the InTouch Access Anywhere Server through a DMZ. The InTouch Access Anywhere Secure Gateway does NOT have any Remote Desktop Services on it, nor does it have any Wonderware licensing.

If I want to use InTouch Access Anywhere via Secure Gateway, the first screen that you will probably see after supplying the Secured Gateway URL (https://<SecuredGateway Node or IP Address>:443/) is the following below. If I have you only have one InTouch Access Anywhere Server, how can you get passed this screen, without constantly having to re-enter the InTouch Access Anywhere server name?

Resolution:

In The URL that you use to connect to the Secured Gateway, you will need to add the parameter of Address separated by "?" at the end of "default.html".

https://SecureGatewayIPAddress:443/AccessAnywhere/default.html?address=InTouchAccessAnywhereNodeName

bypass login
Give feedback about this article

Recommended articles

TN IT106 How-To install InTouch Access Anywhere

Read More

TN IT299 How to have different applications selectable for different users in Intouch Access Anywhere

Read More

TN IT225 How to set a Remote Desktop Timeout Limit for InTouch Access Anywhere

Read More

TN IT330 Unable to log into InTouch Access Anywhere (Password is either expired or must be changed)

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand