Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Intelligence
  • AVEVA Intelligence Tech Notes

TN Intel108 Referencing a Shared Excel Datasource from the Intelligence Analytics Client

Last updated: March 7th, 2025

Description

  • Author: Rich Brooks
  • Published: March 7th, 2025

Details:

Description

This article from InSource shows how to configure a shared Excel datasource when publishing a workbook from the Wonderware Intelligence Analytics client.

  • Author: Rich Brooks
  • Published: 8/17/2016
  • Applies to: Wonderware Intelligence 2014R2 and higher

Details

Wonderware Intelligence data is sometime supplemented with related data from other sources. In this case, data from an Excel spreadsheet is included in a workbook containing Intelligence data. It is important to setup the Excel spreadsheet in a shared location. This will facilitate regular updates to the data on a rolling weekly or monthly basis.

The data source in the Intelligence Analytics client needs to be saved to a shared folder. Click on the name of the Excel workbook as shown circled below.

Enter a UNC path to access the file with the format \\<node name>\<share>\ .

The UNC path needs to include a shared folder that is accessible by the users that will be updating the Excel data.

Select File and Save from the menu to save the changes to the Tableau workbook.

In this example, the Tableau workbook is saved to the same UNC path as the Excel workbook.

Select the Yes button to replace the file, if it already exists.

Click on one of the sheets from the tabs at the bottom of the Intelligence Analytics client.

Select Server and Publish Workbook... from the menu.

The Include External File option must be turned off before publishing. Uncheck the checkbox circled above and then click the Publish button.

You will be prompted to exclude the external files. Click on the Yes button to confirm.

The workbook will be published to the Intelligence (web dashboard) server. Any changes to the Excel data may be made from the shared folder.

excel datasource intelligence analytics
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand