Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Intelligence
  • AVEVA Intelligence Tech Notes

TN Intel107 Adding Filter Actions to an Intelligence Analytics Client Workbook

Last updated: March 7th, 2025

Description

  • Author: Rich Brooks
  • Published: March 7th, 2025

Details:

Description

This article from InSource shows how to add filter actions to an Intelligence Analytics Client (Tableau) workbook.

  • Author: Rich Brooks
  • Published: 6/21/2016
  • Applies to: Wonderware Intelligence 2014R2 or higher

Details

Filter actions may be added to workbooks to create drill down capability. The user is able to hover, select (click on), or right-click on a mark. This provides an easy way to transfer one or more common field(s) between worksheets. The target sheet is filtered on the selected information.

Start by opening an existing Intelligence Analytics client workbook.

Select Worksheet | Actions... from the menu.

Click on the Add Action > button.

Select Filter... from the dialog box.

Give the Filter Action a name by filling in the Name field.

Configure the Source Sheets by selecting a data source from the drop down list.

Select one or more source sheets using the check boxes.

Choose one of the three Run action on options:

  • Hover - rest the mouse over a mark to run the action.
  • Select - click on the mark to run the action.
  • Menu - right-click on the selected mark to open a context menu with an option to run the action.

Configure the Target Sheets by selecting a workbook or dashboard from the drop down list.

Select one or more target sheets using the check boxes.

Choose one of the three radio button options below Clearing selections will:

  • Leave the filter - leaves the filter on the target sheets.
  • Show all values - changes the filter to include all values.
  • Exclude all values - changes the filter to exclude all values.

If you are filtering on Selected Fields, click on the Add Filter button.

Select the Source Field from the drop down list.

Select the Target Data Source and Field from the drop down lists.

Repeat for additional filters, if needed.

Click OK three times to return to the workbook.

filtering actions
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More

How to receive group emails

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand