TN HistClient126 Some domain users are unable to use "Private Groups" from within Historian Client

Last updated: March 4th, 2025

Description

  • Author: Joe Hefner
  • Published: March 4th, 2025

Details:

Description

Some domain users are unable to use "Private Groups" from within Historian Client. This includes being able to create or see existing private groups. This article from InSource walks through some simple things to check to try to resolve this.

  • Author: Joseph Hefner
  • Published: 09/06/2016
  • Applies to: Wonderware Historian 10 or later.

Details

Step 1) Confirm the SQL Server Agent is started. If it is not started, you will see a Red X listed in the bottom right corner as below:

If it is not started, you can start it by right clicking on "SQL Server Agent" and selecting "Start".

If you would like for this service to start automatically, you can go to "Administrative Tools \ Services" and right click on the "SQL Server Agent" Service and go to Properties and change the Startup Type to "Automatic". 

Test creating a private group from within Historian client and if you are still unable to do so try "Step 2" below:

Step 2) Expand the Jobs folder and confirm you see a job called "Update_User_Detail". If this job does not exist try the following.

* Before attempting the steps below make sure to backup the existing runtime database.

  1. Under the Runtime database expand Programmability \ Stored Procedures and locate the procedure called dbo.aaUserDetailUpdate
  2. Right click on dbo.aaUserDetailUpdate and then click the "OK" button at the confirmation screen below:

Test to see if the user can now create and see "Private Groups" from within Historian Client.

private groups domain users
Give feedback about this article

Recommended articles

Historian Client control in InTouch slow to load

Read More

TN 1116 How to determine time between samples

Read More

TN 1267 Historian Client Query Server Configuration Failure

Read More

TN - 1230 Resolving Incorrect server.xml file used after coping server.xml to user profiles

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand