TN - Edge - 26071338 Activate a New or Updated InduSoft Web Studio License

Last updated: July 24th, 2026

Description

  • Author: Adam McKissick
  • Published: July 24th, 2026

Details:

 

  • Document Version: 001
  • Applies to Version(s): InduSoft Web Studio 2020

 

 

Description  

This tech note describes how to activate an InduSoft Web Studio 2020 license using the Softkey protection method. The procedure covers opening the Register utility, checking the current license status, entering the Site Key, authorizing the license, and verifying that the purchased features are available.

Before you begin:

  • Confirm InduSoft Web Studio 2020 is installed on the computer that will run the licensed software.
  • Locate the license fulfillment email received after purchase. It should contain the Site Key, or the Activation Key / Serial Number required to generate the Site Key.
  • Run the Register utility on the same computer where the license will be activated.
  • Use a Windows account with sufficient permissions. If permissions are restricted, run the Register utility as administrator.

Important: License keys and authorization codes are unique to the customer and computer. Do not share or publish Site Keys, Activation Keys, Serial Numbers, Site Codes, or unredacted screenshots containing this information.

Solution Steps:

1. Open the InduSoft Web Studio 2020 Register application

From the Windows Start menu, expand InduSoft Web Studio 2020 and select InduSoft Web Studio 2020 Register. This opens the Protection Manager licensing utility for the local installation.

 

 

2. Select Softkey and run the license check

In Protection Manager, select Softkey as the protection type. Then click Check... to review the current softkey license status and continue to the change-license workflow.

 

 

3. Open Change License

If a license is not currently detected, the Softkey Settings window may show License not found. Click Change License... to enter or update the softkey authorization information.

 

 

4. Enter the Site Key and authorize the license

In the Change License - Softkey dialog, paste the Site Key from the customer's license email or from the activation site. Then click Authorize. If the license email does not include a Site Key, use the Site Code displayed in this window to generate one through the activation site.

 

Obtain the Site Key

The Site Key may be supplied directly in the post-purchase license email. If the email provides an Activation Key or Serial Number instead, generate the Site Key through the InduSoft License Activation site using the Site Code from the target computer.

Resource

When to use it

Link / note

InduSoft License Activation site

Use when the fulfillment email provides an Activation Key / Serial Number and a Site Key must be generated.

InduSoft Activation site

License activation reference video

Use as a visual walkthrough of the license activation process.

Watch the activation video

Verify the result

Confirm the license status no longer shows License not found.

Confirm the product type, execution mode, options, and client counts match the purchased license certificate.

Launch InduSoft Web Studio 2020 and confirm the expected development and runtime features are available.

 

If authorization fails: Record the exact error message and collect the license email details, Activation Key or Serial Number, Site Code, and Site Key used. Redact all license values before sharing screenshots or information in public channels.

Troubleshooting

Symptom

Recommended action

License not found

Open Register, select Softkey, click Check, and then use Change License to enter the Site Key.

Site Key is rejected

Verify the Site Key was generated for the Site Code from the same computer and network adapter. Copy the Site Code again and regenerate the Site Key if necessary.

No Site Key in the license email

Use the InduSoft License Activation site with the Activation Key / Serial Number and Site Code, or contact AVEVA or the licensing vendor for assistance.

  _____________________________________________________________________________________________________

 

indusoft web studio iws license activation
Give feedback about this article

Recommended articles

[ISS Support Case] Attempts to activate a license fails with error, "Error - Unable to activate License. Activation ID . . . is invalid or does not exist. Please verify or contact local Wonderware or AVEVA representative."

Attempts to activate a license fails with error, "Error - Unable to activate License. Activation ID . . . is invalid or does not exist. Please verify or contact local Wonderware or AVEVA representative." The license being used is a 2020x and is being installed on a 2017x platform.

Read More

[ISS Support Case] License Acquisition Failure

Client reached out as when trying to run WindowViewer they would receive a license acquisition failure message. Observed the following error in the logs: Error LicAPISvcProxy.NET Failed to communicate with AVEVA Enterprise License Product Service. Error LicAPISvcProxy.NET Method Details: Void CreateChannelAndEstablishConnection()... Detail="Error starting gRPC call. HttpRequestException: An error occurred while sending the request. WebException: The underlying connection was closed: An unexpected error occurred on a receive. Win32Exception: "The client and server cannot communicate, because they do not possess a common algorithm"

Read More

[ISS Support Case] InTouch License Acquisition Failure

Client reached out due to receiving failure to acquire license when attempting to start WindowViewer.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand