TN DAS146 Configuring the MBTCP DA Server for Communication with a RTAC Device

Last updated: February 20th, 2025

Description

  • Author: Rich Brooks
  • Published: February 20th, 2025

Details:

Description

This article from InSource shows how to configure the Modbus TCP DA Server from Wonderware for communication to a Schweitzer Engineering Laboratories RTAC-SEL3530 device.

  • Author: Rich Brooks
  • Published: 12/11/2016
  • Applies to: DASMBTCP v3.0 SP1

Details

The RTAC device from Schweitzer Engineering Laboratories may be enabled for standard Modbus communication. This article details specific configuration requirements for the Wonderware DASMBTCP device integration protocol. Firstly, the port number needs to match what has been configured in the RTAC. That is if the standard port 502 is not being used. Changing the port number requires editing the configuration XML file.

A Modbus Bridge object is required as a part of the configuration underneath the port object. Be sure to fill in the IP address for the RTAC.

Change the default Maximum outstanding messages from 2 to 1 to avoid repeated disconnects from the device.

The Modbus PLCRS object is added beneath the bridge object. There are specific selections that are required for the RTAC device.

This is displaying what worked for me, but some of these settings depend on how the RTAC has been programmed for Modbus. You may use this as a starting point to test out the I/O communication.

The item addressing format used in Wonderware InTouch and Historian for this example configuration is listed below.

The analogs tags that span two registers need an L (signed) or U (unsigned) following the address number.

configure rtac
Give feedback about this article

Recommended articles

TN 1242 Aveva Historian Storage Locations and Best Practices

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand