Details:

Description

This article from InSource walks through the process for backing up a Wonderware InBatch application.

  • Author: Joseph Hefner
  • Published: 06/06/2017
  • Applies to: Wonderware InBatch 2012 and above

Details

1) Backup the InBatch Config_a files 

The project files are usually contained in the location below:
C:\Program Files (x86)\Wonderware\InBatch\cfg


2) On the Batch History server, backup the BatchHistory and BatchArchive databases

This can be done from within SQL Server Management studio by right clicking on the databases and choosing "Tasks \ Backup"



3) Backup the DA Server configuration:

The link below contains instructions for backing up the DA Server configuration

https://insource.mindtouch.us/Wonderware_Device_Integration_and_Communication/Tech_Notes/Migrating_DA_Server_configuration_to_a_New_PC

4) For versions prior to InBatch 2014 R3, backup Information server from the backup restore tool.

The link below contains instructions for backing up Wonderware Information Server.

https://insource.mindtouch.us/Wonderware_Information_Server/Tech_Notes/TN_WIS107_How_to_backup_Wonderware_Information_Server

5) For InBatch 2014 R3 and above:

The link below walks through an approach for backing up SSRS reports:

https://insource.mindtouch.us/Wonderware_Historian_Server/Tech_Notes/Working_Content_2015/Backing_up_a_Wonderware_InBatch_application?mt-draft=falseSSRS)_Reports_using_Report_Builder?mt-draft=false

inbatch backup data protection
Give feedback about this article

Recommended articles

TN 1242 Aveva Historian Storage Locations and Best Practices

Read More

Aveva Diagnostic Utility wwClient

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand