TN - AppSrv2603241501 Unable to Create a Galaxy

Last updated: March 24th, 2026

Description

  • Author: Ernest Lee
  • Published: March 24th, 2026

Details:

Details: This Tech Note addresses an issue where users are unable to create a Galaxy in Application Server 2023 R2 SP1 due to a SQL Server connection failure related to a file version mismatch of Microsoft.Identity.Client.dll. 555

 

Applies to: Application Server 2023 R2 SP1 6

 

Issue

Creating a Galaxy Failed With Following Message: 7

 

Failed to find the galaxy database 'RMN' in SQL Server 'localhost'. Error: Microsoft.SqlServer.Management.Common.ConnectionFailureException: Failed to connect to server localhost. 8---> System.TypeInitializationException: The type initializer for 'Microsoft.Data.SqlClient.SqlAuthenticationProviderManager' threw an exception. 9---> System.IO.FileLoadException: Could not load file or assembly 'Microsoft.Identity.Client, Version = 4.64.0.0' or one of its dependencies. 10

The located assembly's manifest definition does not match the assembly reference. (Exception from HRESULT: 0x80131040) 11

 

Cause

There is a mismatch with the file version for Microsoft.Identity.Client.dll within the ArchestrA framework folders. 12

 

Resolution

  1. Locate the file Microsoft.Identity.Client.dll in the folder: C:\Program Files (x86)\ArchestrA\Framework\Bin. This version is typically v4.56.0.0. 13

2. Locate the file Microsoft.Identity.Client.dll in the folder: C:\Program Files (x86)\ArchestrA\Framework\Bin\SMOSupport. This version is typically v4.61.3.0. 14

3. Take a backup of the file located in the first folder (Step 1). 15

4. Replace the file in the first folder with a copy of the file found in the second folder (Step 2). 16

 

Restart the machine to resolve the issue. 17

 


creation galaxy
Give feedback about this article

Recommended articles

[ISS Support Case] IDE - unable to create a new galaxy

Error message: service could not be started either because it is disabled

Read More

[ISS Support Case] System Platform - Can't Create Galaxy

Customer called in saying they can't create a galaxy. Called the customer back, but he left the site and isn't sure when he'll be back.

Read More

[ISS Support Case] Unable to Create a galaxy

Creating New galaxy in the default galaxy type and it is not allowing him to do so.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand