Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Application Server
  • AVEVA Application Server Tech Notes

TN DAS164 How To Copy the Configuration of a DA Server From One Machine to Another

Last updated: February 20th, 2025

Description

  • Author: Brian Schneider
  • Published: February 20th, 2025

Details:

Description

This article from InSource shows...

  • Author: Peter Farrell
  • Published: 06/29/2017
  • Applies to: DA Server all versions

Details

To copy the configuration of a DA server from one machine to another – 

  1. Open Windows Explorer on the machine on which the DA Server is installed.
  2. Navigate to c:\ProgramData\Wonderware\DAServer\DASABCI
  3. Look for a file called DASABCIP.aacf
  4. Copy the DASABCIP.aacfg file to the other computer on which the DASABCIP DA server is installed and for which you need to have the same configuration.
  5. Open the SMC and navigate to the DASABCIP DA Server under the DA Server Manager or Operations Integration Manager and you should see all of the configured PLCs, etc.

    This process works for all DA Servers. You would just copy the appropriate aacfg file from the appropriate folder under c:\ProgramData\Wonderware\DAServer path. For example, to copy the configuration for a DASMBTCP DA server it would be the DASMBTCP.aacfg file from c:\ProgramData\Wonderware\DAServer\DASMBTCP\

    On some systems you can’t see the ProgramData folder off the c: drive. You can either manually enter the path as shown below in the Windows Explorer path dialog, or you can turn on the view to ProgramData from the View Options menu in Windows Explorer (see 2nd screen shot below)

    If the OS is Windows 2003 or XP, the path is:

    C:\Documents and Settings\All Users\Application Data\Wonderware\DAServer\DASABCIP
transfer replicate
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More

TN 1242 Aveva Historian Storage Locations and Best Practices

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand