TN 1406 Error upon creating a Galaxy "Unexpected failure (8000ffff) raised at line...."

Last updated: March 6th, 2025

Description

  • Author: Glenn Yancey
  • Published: March 6th, 2025

Details:

Description

This article from InSource shows one possible solution when getting the error upon creating a Galaxy "Unexpected failure (8000ffff) raised at line....".

  • Author: Glenn Yancey
  • Published: 12/8/2023
  • Applies to: System Platform 2020 and above

Details

When creating a Galaxy, it is very possible that one could immediately see an error within seconds after selecting to Create a Galaxy. In many cases this issue is resolved by making sure that your aaAdminUser (Change Network Account) needing to be reset, but it is also possible that it could be related to SQL Server and its protocol being encrypted.

In Today's time, setting up encryption is one method that many are doing to safeguard their networks for any external intrusions. SQL Server does offer encryption as a layer on its protocol.

The main reason why a connection between SQL Server instance and any client application should be encrypted is authorized communication between them. This security layer can prevent unwanted sensitive data leak, or exclude the possibility for any SQL injection attack, e.g.

This is usually a setting that is manually turned ON, so in this scenario, it was turned on the base image being used to create their VM images with SQL. Having this set to on can immediately cause the IDE to fail immediately upon Galaxy Creation.

To Verify if this is the issue.

  1. Open up the SQL Server Configuration Manager (NOT THE SQL SERVER MANAGEMENT STUDIO).
  2. Expand SQL Server Network Configuration.
    1. Right Click on Protocol for MSSQLSERVER
  3. If Set to Yes, THEN Set Force Encryption to NO.
  4. Reboot and Test.

 

After turning off, you should be able to create a galaxy. 

8000ffff failure galaxy creation
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More

TN 1242 Aveva Historian Storage Locations and Best Practices

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand