Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Application Server
  • AVEVA Application Server Tech Notes

TN - AppSrv - 26051811 Could not resolve reference; (myengine.engine.historian.connection)

Last updated: May 21st, 2026

Description

  • Author: Sam Soens
  • Published: May 21st, 2026

Details:

  • Document Version: 001
  • Applies to Version(s):  All versions up to and including 2023x

 

 

Description  

This Technote outlines an error sometimes seen with Application Server object graphics and a common resolution.

A graphic may not work properly, and in Log Viewer you might find:

Could not resolve reference; (myengine.engine.historian.connection)

Solution Steps:

The graphic should be part of an object under the engine referenced. Ensure the graphic is not standalone in the Graphic Toolbox. If it is not tied to an object assigned to the engine, it will not be able to resolve the myengine reference.

Secondly, make sure the hosting engine is configured to Historize. If it isn't, it can also throw this error message. 

 

_____________________________________________________________________________________________________

 

documentation template
Give feedback about this article

Recommended articles

[ISS Support Case] Not writing to historian

2 platforms not writing to historian. please update historian server properties with valid credentials

Read More

[ISS Support Case] Historian Data Importer Failure

Client reached out as when attempting to import any CSV data into the Historian data importer it fails with the same error message: "Error processing the file. Error in line number 2. Unsupported delimiter." This was tested with multiple unique CSV's exported from both Query and Trend.

Read More

[ISS Support Case] Historian missing data

A month ago they changed the network acct utility. Missing data from 9/7 - 10/30, data starting coming in after they re-ran the change network acct utility again. ?Using tiered historian.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand