Description

This article from InSource Solutions shows you how to use the Galaxy .cab file to determine an Application Server version.

  • Author: Daniel London
  • Published: 02/18/2019
  • Applies to: Application Server

 

Details

The instructions below show you how to use the _GalaxyInfo.txt file inside of a .cab folder to determine the version of Application Server.

  1. Rename the .cab file type to .zip.

Rename Cab.JPG

 

  1. Click Yes.

Click Yes.JPG

 

  1. Open the _GalaxyInfo.txt file in the .zip folder.

Open Zip Folder.JPG

 

  1. Record the CDI Version Number.

CDI Version.JPG

 

The list below outlines the different CDI version numbers and which product they coincide with:

IAS 2.1]
2.1 Release: 2559.1144.0.0
2.1 P01: 2559.1144.66.12
2.1 P02: 2559.1144.77.14

[WAS 3.0]
3.0 Release: 2859.1293.0.0
3.0 P01: 2859.1293.24.2
3.0 P02: 2859.1293.53.4
3.0 P03: 2859.1293.70.5
3.0 SP1: 2859.1293.95.15
3.0 SP2: 2859.1293.239.40

[WAS 3.1]
3.1 Release: 3132.57.0.0
3.1 SP1: 3132.57.24.6
3.1 SP2: 3132.57.91.24
3.1 SP2 P01: 3132.57.103.28
3.1 SP3: 3132.57.119.34
3.1 SP3 P01: 3132.57.160.38

[ASP 2012]
3.5 Release: 3275.0113.0000.0000
3.5 P01: 3275.113.110.8

[ASP 2012 R2]
3.6: 3388.0127.0000.0000
3.6 P01: 3388.0127.0126.0006
3.6 P02: 3388.0127.0212.0011
3.6 P03: 3388.0127.0300.0012

[WSP 2014]
4.0: 3509.0148.0000.0000
4.0 P01: 3509.0148.0140.0007

[WSP 2014R2]
4.1 Release: 3735.0233.0000.0000
4.1 P01: 3735.0233.0223.0032
4.1 SP1: 3735.0233.0399.0061
4.1 SP1P1: 3735.0233.0399.0061
4.1 SP1P2: 3735.0233.0776.0085

[WSP 2017]
17.0: 4148.0279.0000.0000
17.1: 4545.0291.0000.0000
17.2: 5019.0376.0000.0000
17.3: 5543.0474.0000.0000