Skip to main content
InSource Solutions

TN VMW106 VMWare Internal Switch for Redundant Virtual Application Object Servers

Description

This article from Insource shows how to create a VMWare Internal Switch for RMC when object servers reside on the same VMware host(Crossover cable not required)

 

This article from InSource shows...How to Create a VMWare Internal Switch for RMC when Objects Servers reside on the same VMWare host

  • Author: Mike Viteri
  • Published: 03/20/2016
  • Applies to: VMWare & Application Server

Details

  • Select the VMhost where your VM's are running.  Click on the "configuration" tab

networking.JPG

 

  • Select Add Networking on the right hand side

networking2.JPG

  • Select Virtual Machine as the default

networking3.JPG

  • Uncheck all physical network adapters. This will create an internal switch on host. You should "No Adapters" Under physical adapters. Click next when done.

networking4.JPG

  • Rename the Network Label to RMC. Click next

networking5.JPG

  • Your switch should look like the graphic below. Click Finish.

networking6.JPG

  • Under your VMware configuration->networking you should now your see the RMC switch. Now in each AOS VM you can add a second network adapter and use application server redundancy. 

networking7.JPG