Skip to main content
InSource KnowledgeCenter

TN WW121 Wonderware Software Versions Index

insource logo large.jpg

 

Description

This article lists all of the currently supported versions for Wonderware Software. Thank you to Wonderware PacWest for the content.

 

  • Author: Daniel London
  • Published: 08/28/2015
  • Applies to: All Supported Software Versions

 

Details

The content below lists all supported versions of Wonderware Software

InTouch

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2 (11.1)
12/16/2014
None 12/16/2017
12/16/2019

Current Version

2014 (11.0)
1/2/2014
Patch01
(11.0.001)

6/2/2014
1/2/2017
1/2/2019

Mainstream Support through 1/2/2017

2012 R2 (10.6)
12/13/2012
Patch03
(10.6.003)

10/15/2014
12/13/2015
12/13/2017

Mainstream Support through 12/13/2015

2012 (10.5)
11/21/2011
Patch01
(10.5.001)

6/11/2012
11/21/2014
11/21/2016

Extended Support through 11/21/2016

10.1
3/9/2009
SP3 Patch01
(10.1.301)

5/12/2011
3/9/2012
3/9/2014

Mature Support

Historian

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2 (11.6)
12/16/2014
None 12/16/2017
12/16/2019

Current Version

2014 (11.5)
1/2/2014
Patch01
(11.5.001)

6/2/2014
1/2/2017
1/2/2019

Mainstream Support through 1/2/2017

2012 R2 (11.0)
12/13/2012
Patch03
(10.6.003)

10/15/2014
12/13/2015
12/13/2017

Mainstream Support through 12/13/2015

2012 (10.0)
2/1/2010
SP1 Patch01
(10.0.101)

8/24/2012
2/1/2013
2/1/2015

Mature Support

Historian Client

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2 (10.6)
12/16/2014
None 12/16/2017
12/16/2019

Current Version

2014 (10.5)
1/2/2014
Patch01
(10.5.001)

6/2/2014
1/2/2017
1/2/2019

Mainstream Support through 1/2/2017

2012 R2 (10.1)
12/13/2012
Patch03
(10.6.003)

10/15/2014
12/13/2015
12/13/2017

Mainstream Support through 12/13/2015

2012 (10.0)
3/8/2010
SP2
(10.0.200)

4/6/2011
3/8/2013
3/8/2015

Mature Support

Application Server (ArchestrA Common Services)

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2 (4.1)
12/16/2014
None 12/16/2017
12/16/2019

Current Version

2014 (4.0)
1/2/2014
Patch01
(4.0.001)

6/2/2014
1/2/2017
1/2/2019

Mainstream Support through 1/2/2017

2012 R2 (3.6)
12/13/2012
Patch03
(10.6.003)

10/15/2014
12/13/2015
12/13/2017

Mainstream Support through 12/13/2015

2012 (3.5)
11/21/2011
SP1
(3.5.100)

9/11/2012
11/21/2014
11/21/2016

Extended Support through 11/21/2016

3.1
3/9/2009
SP3 Patch01
(3.1.301)

5/12/2011
3/9/2012
3/9/2014

Mature Support

Information Server

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2 (5.6)
12/16/2014
None 12/16/2017
12/16/2019

Current Version

2014 (5.5)
1/2/2014
Patch02
(5.5.002)

8/18/2014
1/2/2017
1/2/2019

Mainstream Support through 1/2/2017

2012 R2 (5.0)
12/13/2012
Patch03
(10.6.003)

10/15/2014
12/13/2015
12/13/2017

Mainstream Support through 12/13/2015

2012 (4.5)
11/21/2011
None 11/21/2014
11/21/2016

Extended Support through 11/21/2016

4.0
4/5/2010
SP1
(4.0.100)

4/6/2011
4/5/2013
4/5/2015

Mature Support

Skelta BPM (Workflow)

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2
3/30/2015
None 3/30/2018
3/30/2020

Current Version

2014
9/19/2014
Patch01
10/28/2014
9/19/2017
9/19/2019

Mainstream Support through 9/19/2017

2012 R2
5/14/2013
SP1
12/19/2013
5/14/2016
5/14/2018

Mainstream Support through 5/14/2016

2012
11/29/2011
SP1 Patch01
12/20/2012
11/29/2014
11/29/2016

Extended Support through 11/29/2016

1.1
4/27/2011
None 4/27/2014
4/27/2016

Extended Support through 4/27/2016

1.0
2/24/2011
None 2/24/2014
2/24/2016

Extended Support through 2/24/2016

Corporate Energy Management

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2
1/28/2015
None 1/28/2018
1/28/2020

Current Version

2012 R2
7/3/2013
None 7/3/2016
7/3/2018

Mainstream Support through 7/3/2016

2012
11/13/2012
None 11/13/2015
11/13/2017

Mainstream Support through 11/13/2015

1.2
3/2/2012
None 3/2/2015
3/2/2017

Extended Support through 3/2/17

1.1
3/11/2011
None 3/11/2013
3/11/2016

Extended Support through 3/11/2016

1.0
4/8/2010
None 4/8/2013
4/8/2015

Mature Support

Manufacturing Execution System (MES)

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014
10/27/2014
SP1
3/17/2015
10/27/2017
10/27/2019

Current Version

2012 (4.5)
9/17/2012
Patch01
(4.5.001)

3/8/2013
9/17/2015
9/17/2017

Mainstream Support through 9/17/2015

4.0
5/3/2010
SP2
(4.0.200)

5/29/2012
5/3/2013
5/3/2015

Extended Support through 5/3/2015

3.5
12/8/2008
Patch02
(3.5.002)

9/13/2011
12/8/2011
12/8/2013

Mature Support

Intelligence

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2012
3/30/2012
SP1
(1.5.100)

3/30/2012
3/30/2015
3/30/2017

Current Version

1.5
9/16/2011
None 9/16/2014
9/16/2016

Extended Support through 9/16/2016

1.1
1/7/2011
None 1/7/2014
1/7/2016

Extended Support through 1/7/2016

1.0
12/7/2010
SP1
(1.0.100)

5/10/2010
12/7/2013
12/7/2015

Extended Support through 12/7/2015

IntelaTrac

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
5.0
10/13/2014
SP1
1/16/2015
10/13/2017
10/13/2019

Current Version

4.3
11/20/2013
SP2
(4.2.200)

7/8/2014
11/20/2016
11/20/2018

Mainstream Support through 11/20/2016

4.2
4/22/2012
SP2 Patch03
(4.2.203)

4/29/2013
4/22/2015
4/22/2017

Mainstream Support through 11/20/2015

4.1
4/5/2011
SP2 Patch07
(4.1.207)

5/21/2012
4/5/2014
4/5/2016

Extended Support through 4/5/2016

4.0
2/1/2010
None 2/1/2013
2/1/2015

Mature Support

InBatch

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2 (10.2)
2/4/2015
None 2/4/2018
2/4/2020

Current Version

2014 (10.1)
3/17/2014
None 3/17/2017
3/17/2019

Mainstream Support through 3/17/2017

2012 R2 (10.0)
3/28/2013
None 3/28/2016
3/28/2018

Mainstream Support through 3/28/2016

2012 (9.6)
9/17/2012
None 9/17/2015
9/17/2017

Mainstream Support through 9/17/2015

9.5
9/23/2011
SP1
(9.5.100)

3/22/2012
9/23/2014
9/23/2016

Extended Support through 9/23/2016

9.0
3/20/2009
SP2
(9.0.200)

4/19/2011
3/20/2012
3/20/2014

Mature Support

Recipe Manager Plus

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2
3/30/2015
None 3/30/2018
3/30/2020

Current Version

2014
4/10/2014
SP1
(1.0.100)

7/7/2014
4/10/2017
4/10/2019

Mainstream Support through 4/10/2017

SmartGlance

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2
10/20/2014
Patch01
1/4/2015
10/20/2017
10/20/2019

Current Version

2014
7/9/2014
Patch01
10/29/2014
7/9/2017
7/9/2019

Mainstream Support through 7/9/2017

Alarm Adviser

Major Version and Release Date Latest Patch
(Full Version No.)
and Release Date
Mainstream
and Extended
Support through
Notes
2014 R2
4/5/2015
None 4/5/2018
4/5/2020

Current Version

Definitions of Support Levels

Mainstream Support

Upon the Date of General Availability, a product version will enter Mainstream Support. This phase of the product life will have a three (3) year term during which Customer FIRST Support subscribers are entitled to the following services:

  • Technical Assistance on Issues and Inquiries via Existing Support Programs
  • Patches & Service Packs
    • To address product issues
    • To support critical OS security updates
  • Ability to request Hot Fixes

Extended Support

Upon retirement of Mainstream Support, the product will enter Extended Support. During this two (2) year period, Customer FIRST Support subscribers will be provided the following services:

  • Technical Assistance on Issues and Inquiries via Existing Support Programs
  • Ability to Request Hot Fixes
    • To address product issues
    • Support (limited) for Critical OS Security Updates

Mature Product Support

The final phase of Wonderware Lifecycle Support covers product releases in the mature software life phase. The Mature Support phase follows the 5 years of coverage provided by Mainstream and Extended phases by offering on-going technical assistance to customers maintaining installed product. Mature Support includes:

  • Technical Assistance via existing programs

Technical Assistance in the Mature Support phase involves providing basic issue diagnostics assistance from the available database of technical knowledge. In depth issue research should not be anticipated at this phase. Customers encountering issues which have been resolved in a more current release of the product will be advised to upgrade their product version to resolve the issue.

 

Source:

https://wonderwarepacwest.com/support/product-versions/