TN Hist238 Historian Quality Detail Value and Description list

insource logo large.jpg

 

Description

The list below shows each quality detail value available in the Historian. It will also show what the description of the quality value.

 

  • Author: Mike Viteri
  • Published: 11/12/2015
  • Applies to: Historian

 

 

Details

 

Quality.JPG

 

0 Bad Quality of undetermined state
1 No data available, tag did not exist at the time
2 Running insert
10 Communication loss
16 Good value, received out of time sync (cyclic tag)
17 Duplicate time stamp; infinite slope
20 IDAS overflow recovery
24 IOServer communication failed
33 Violation of History Duration license feature
44 Pipe reconnect
64 Cannot convert
150 Storage startup
151 Store forward storage startup
192 Good
202 Good point of version Latest
212 Counter rollover has occurred
248 First value received in store forward mode
249 Not a number
252 First value received from IOServer
256 Bad Quality of undetermined state, timestamp overwritten; values in future
257 No data available, tag did not exist at the time, timestamp overwritten; values in future
258 Running insert, timestamp overwritten; values in future
266 Communication loss, timestamp overwritten; values in future
272 Good value, received out of time sync (cyclic tag), timestamp overwritten; values in future
273 Duplicate time stamp; infinite slope, timestamp overwritten; values in future
276 IDAS overflow recovery, timestamp overwritten; values in future
280 IOServer communication failed, timestamp overwritten; values in future
300 Pipe reconnect, timestamp overwritten; values in future
320 Cannot convert, timestamp overwritten; values in future
406 Storage startup, timestamp overwritten; values in future
407 Store forward storage startup, timestamp overwritten; values in future
448 Good, timestamp overwritten; values in future
458 Good point of version Latest, timestamp overwritten; values in future
468 Counter rollover has occurred, timestamp overwritten; values in future
504 First value received in store forward mode, timestamp overwritten; values in future
505 Not a number, timestamp overwritten; values in future
508 First value received from IOServer, timestamp overwritten; values in future
512 Bad Quality of undetermined state, timestamp overwritten; values out of time sequence
513 No data available, tag did not exist at the time, timestamp overwritten; values out of time sequence
514 Running insert, timestamp overwritten; values out of time sequence
522 Communication loss, timestamp overwritten; values out of time sequence
528 Good value, received out of time sync (cyclic tag), timestamp overwritten; values out of time sequence
529 Duplicate time stamp; infinite slope, timestamp overwritten; values out of time sequence
532 IDAS overflow recovery, timestamp overwritten; values out of time sequence
536 IOServer communication failed, timestamp overwritten; values out of time sequence
556 Pipe reconnect, timestamp overwritten; values out of time sequence
576 Cannot convert, timestamp overwritten; values out of time sequence
662 Storage startup, timestamp overwritten; values out of time sequence
663 Store forward storage startup, timestamp overwritten; values out of time sequence
704 Good, timestamp overwritten; values out of time sequence
714 Good point of version Latest, timestamp overwritten; values out of time sequence
724 Counter rollover has occurred, timestamp overwritten; values out of time sequence
760 First value received in store forward mode, timestamp overwritten; values out of time sequence
761 Not a number, timestamp overwritten; values out of time sequence
764 First value received from IOServer, timestamp overwritten; values out of time sequence
1024 Bad Quality of undetermined state, timestamp overwritten; server timestamping selected
1025 No data available, tag did not exist at the time, timestamp overwritten; server timestamping selected
1026 Running insert, timestamp overwritten; server timestamping selected
1034 Communication loss, timestamp overwritten; server timestamping selected
1040 Good value, received out of time sync (cyclic tag), timestamp overwritten; server timestamping selected
1041 Duplicate time stamp; infinite slope, timestamp overwritten; server timestamping selected
1044 IDAS overflow recovery, timestamp overwritten; server timestamping selected
1048 IOServer communication failed, timestamp overwritten; server timestamping selected
1068 Pipe reconnect, timestamp overwritten; server timestamping selected
1088 Cannot convert, timestamp overwritten; server timestamping selected
1174 Storage startup, timestamp overwritten; server timestamping selected
1175 Store forward storage startup, timestamp overwritten; server timestamping selected
1216 Good, timestamp overwritten; server timestamping selected
1226 Good point of version Latest, timestamp overwritten; server timestamping selected
1236 Counter rollover has occurred, timestamp overwritten; server timestamping selected
1272 First value received in store forward mode, timestamp overwritten; server timestamping selected
1273 Not a number, timestamp overwritten; server timestamping selected
1276 First value received from IOServer, timestamp overwritten; server timestamping selected
2048 Bad Quality of undetermined state, intermediate point stored by deadband storage algorithm
2049 No data available, tag did not exist at the time, intermediate point stored by deadband storage algorithm
2050 Running insert, intermediate point stored by deadband storage algorithm
2058 Communication loss, intermediate point stored by deadband storage algorithm
2064 Good value, received out of time sync (cyclic tag), intermediate point stored by deadband storage algorithm
2065 Duplicate time stamp; infinite slope, intermediate point stored by deadband storage algorithm
2068 IDAS overflow recovery, intermediate point stored by deadband storage algorithm
2072 IOServer communication failed, intermediate point stored by deadband storage algorithm
2092 Pipe reconnect, intermediate point stored by deadband storage algorithm
2112 Cannot convert, intermediate point stored by deadband storage algorithm
2198 Storage startup, intermediate point stored by deadband storage algorithm
2199 Store forward storage startup, intermediate point stored by deadband storage algorithm
2240 Good, intermediate point stored by deadband storage algorithm
2250 Good point of version Latest, intermediate point stored by deadband storage algorithm
2260 Counter rollover has occurred, intermediate point stored by deadband storage algorithm
2296 First value received in store forward mode, intermediate point stored by deadband storage algorithm
2297 Not a number, intermediate point stored by deadband storage algorithm
2300 First value received from IOServer, intermediate point stored by deadband storage algorithm
2304 Bad Quality of undetermined state, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2305 No data available, tag did not exist at the time, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2306 Running insert, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2314 Communication loss, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2320 Good value, received out of time sync (cyclic tag), timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2321 Duplicate time stamp; infinite slope, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2324 IDAS overflow recovery, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2328 IOServer communication failed, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2348 Pipe reconnect, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2368 Cannot convert, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2454 Storage startup, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2455 Store forward storage startup, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2496 Good, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2506 Good point of version Latest, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2516 Counter rollover has occurred, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2552 First value received in store forward mode, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2553 Not a number, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2556 First value received from IOServer, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm
2560 Bad Quality of undetermined state, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2561 No data available, tag did not exist at the time, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2562 Running insert, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2570 Communication loss, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2576 Good value, received out of time sync (cyclic tag), timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2577 Duplicate time stamp; infinite slope, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2580 IDAS overflow recovery, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2584 IOServer communication failed, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2604 Pipe reconnect, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2624 Cannot convert, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2710 Storage startup, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2711 Store forward storage startup, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2752 Good, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2762 Good point of version Latest, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2772 Counter rollover has occurred, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2808 First value received in store forward mode, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2809 Not a number, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
2812 First value received from IOServer, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm
3072 Bad Quality of undetermined state, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3073 No data available, tag did not exist at the time, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3074 Running insert, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3082 Communication loss, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3088 Good value, received out of time sync (cyclic tag), timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3089 Duplicate time stamp; infinite slope, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3092 IDAS overflow recovery, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3096 IOServer communication failed, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3116 Pipe reconnect, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3136 Cannot convert, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3222 Storage startup, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3223 Store forward storage startup, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3264 Good, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3274 Good point of version Latest, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3284 Counter rollover has occurred, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3320 First value received in store forward mode, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3321 Not a number, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
3324 First value received from IOServer, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm
4096 Bad Quality of undetermined state, partial cycle
4097 No data available, tag did not exist at the time, partial cycle
4098 Running insert, partial cycle
4106 Communication loss, partial cycle
4112 Good value, received out of time sync (cyclic tag), partial cycle
4113 Duplicate time stamp; infinite slope, partial cycle
4116 IDAS overflow recovery, partial cycle
4120 IOServer communication failed, partial cycle
4140 Pipe reconnect, partial cycle
4160 Cannot convert, partial cycle
4246 Storage startup, partial cycle
4247 Store forward storage startup, partial cycle
4288 Good, partial cycle
4298 Good point of version Latest, partial cycle
4308 Counter rollover has occurred, partial cycle
4344 First value received in store forward mode, partial cycle
4345 Not a number, partial cycle
4348 First value received from IOServer, partial cycle
4352 Bad Quality of undetermined state, timestamp overwritten; values in future, partial cycle
4353 No data available, tag did not exist at the time, timestamp overwritten; values in future, partial cycle
4354 Running insert, timestamp overwritten; values in future, partial cycle
4362 Communication loss, timestamp overwritten; values in future, partial cycle
4368 Good value, received out of time sync (cyclic tag), timestamp overwritten; values in future, partial cycle
4369 Duplicate time stamp; infinite slope, timestamp overwritten; values in future, partial cycle
4372 IDAS overflow recovery, timestamp overwritten; values in future, partial cycle
4376 IOServer communication failed, timestamp overwritten; values in future, partial cycle
4396 Pipe reconnect, timestamp overwritten; values in future, partial cycle
4416 Cannot convert, timestamp overwritten; values in future, partial cycle
4502 Storage startup, timestamp overwritten; values in future, partial cycle
4503 Store forward storage startup, timestamp overwritten; values in future, partial cycle
4544 Good, timestamp overwritten; values in future, partial cycle
4554 Good point of version Latest, timestamp overwritten; values in future, partial cycle
4564 Counter rollover has occurred, timestamp overwritten; values in future, partial cycle
4600 First value received in store forward mode, timestamp overwritten; values in future, partial cycle
4601 Not a number, timestamp overwritten; values in future, partial cycle
4604 First value received from IOServer, timestamp overwritten; values in future, partial cycle
4608 Bad Quality of undetermined state, timestamp overwritten; values out of time sequence, partial cycle
4609 No data available, tag did not exist at the time, timestamp overwritten; values out of time sequence, partial cycle
4610 Running insert, timestamp overwritten; values out of time sequence, partial cycle
4618 Communication loss, timestamp overwritten; values out of time sequence, partial cycle
4624 Good value, received out of time sync (cyclic tag), timestamp overwritten; values out of time sequence, partial cycle
4625 Duplicate time stamp; infinite slope, timestamp overwritten; values out of time sequence, partial cycle
4628 IDAS overflow recovery, timestamp overwritten; values out of time sequence, partial cycle
4632 IOServer communication failed, timestamp overwritten; values out of time sequence, partial cycle
4652 Pipe reconnect, timestamp overwritten; values out of time sequence, partial cycle
4672 Cannot convert, timestamp overwritten; values out of time sequence, partial cycle
4758 Storage startup, timestamp overwritten; values out of time sequence, partial cycle
4759 Store forward storage startup, timestamp overwritten; values out of time sequence, partial cycle
4800 Good, timestamp overwritten; values out of time sequence, partial cycle
4810 Good point of version Latest, timestamp overwritten; values out of time sequence, partial cycle
4820 Counter rollover has occurred, timestamp overwritten; values out of time sequence, partial cycle
4856 First value received in store forward mode, timestamp overwritten; values out of time sequence, partial cycle
4857 Not a number, timestamp overwritten; values out of time sequence, partial cycle
4860 First value received from IOServer, timestamp overwritten; values out of time sequence, partial cycle
5120 Bad Quality of undetermined state, timestamp overwritten; server timestamping selected, partial cycle
5121 No data available, tag did not exist at the time, timestamp overwritten; server timestamping selected, partial cycle
5122 Running insert, timestamp overwritten; server timestamping selected, partial cycle
5130 Communication loss, timestamp overwritten; server timestamping selected, partial cycle
5136 Good value, received out of time sync (cyclic tag), timestamp overwritten; server timestamping selected, partial cycle
5137 Duplicate time stamp; infinite slope, timestamp overwritten; server timestamping selected, partial cycle
5140 IDAS overflow recovery, timestamp overwritten; server timestamping selected, partial cycle
5144 IOServer communication failed, timestamp overwritten; server timestamping selected, partial cycle
5164 Pipe reconnect, timestamp overwritten; server timestamping selected, partial cycle
5184 Cannot convert, timestamp overwritten; server timestamping selected, partial cycle
5270 Storage startup, timestamp overwritten; server timestamping selected, partial cycle
5271 Store forward storage startup, timestamp overwritten; server timestamping selected, partial cycle
5312 Good, timestamp overwritten; server timestamping selected, partial cycle
5322 Good point of version Latest, timestamp overwritten; server timestamping selected, partial cycle
5332 Counter rollover has occurred, timestamp overwritten; server timestamping selected, partial cycle
5368 First value received in store forward mode, timestamp overwritten; server timestamping selected, partial cycle
5369 Not a number, timestamp overwritten; server timestamping selected, partial cycle
5372 First value received from IOServer, timestamp overwritten; server timestamping selected, partial cycle
6144 Bad Quality of undetermined state, intermediate point stored by deadband storage algorithm, partial cycle
6145 No data available, tag did not exist at the time, intermediate point stored by deadband storage algorithm, partial cycle
6146 Running insert, intermediate point stored by deadband storage algorithm, partial cycle
6154 Communication loss, intermediate point stored by deadband storage algorithm, partial cycle
6160 Good value, received out of time sync (cyclic tag), intermediate point stored by deadband storage algorithm, partial cycle
6161 Duplicate time stamp; infinite slope, intermediate point stored by deadband storage algorithm, partial cycle
6164 IDAS overflow recovery, intermediate point stored by deadband storage algorithm, partial cycle
6168 IOServer communication failed, intermediate point stored by deadband storage algorithm, partial cycle
6188 Pipe reconnect, intermediate point stored by deadband storage algorithm, partial cycle
6208 Cannot convert, intermediate point stored by deadband storage algorithm, partial cycle
6294 Storage startup, intermediate point stored by deadband storage algorithm, partial cycle
6295 Store forward storage startup, intermediate point stored by deadband storage algorithm, partial cycle
6336 Good, intermediate point stored by deadband storage algorithm, partial cycle
6346 Good point of version Latest, intermediate point stored by deadband storage algorithm, partial cycle
6356 Counter rollover has occurred, intermediate point stored by deadband storage algorithm, partial cycle
6392 First value received in store forward mode, intermediate point stored by deadband storage algorithm, partial cycle
6393 Not a number, intermediate point stored by deadband storage algorithm, partial cycle
6396 First value received from IOServer, intermediate point stored by deadband storage algorithm, partial cycle
6400 Bad Quality of undetermined state, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6401 No data available, tag did not exist at the time, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6402 Running insert, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6410 Communication loss, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6416 Good value, received out of time sync (cyclic tag), timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6417 Duplicate time stamp; infinite slope, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6420 IDAS overflow recovery, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6424 IOServer communication failed, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6444 Pipe reconnect, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6464 Cannot convert, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6550 Storage startup, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6551 Store forward storage startup, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6592 Good, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6602 Good point of version Latest, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6612 Counter rollover has occurred, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6648 First value received in store forward mode, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6649 Not a number, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6652 First value received from IOServer, timestamp overwritten; values in future, intermediate point stored by deadband storage algorithm, partial cycle
6656 Bad Quality of undetermined state, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6657 No data available, tag did not exist at the time, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6658 Running insert, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6666 Communication loss, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6672 Good value, received out of time sync (cyclic tag), timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6673 Duplicate time stamp; infinite slope, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6676 IDAS overflow recovery, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6680 IOServer communication failed, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6700 Pipe reconnect, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6720 Cannot convert, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6806 Storage startup, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6807 Store forward storage startup, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6848 Good, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6858 Good point of version Latest, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6868 Counter rollover has occurred, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6904 First value received in store forward mode, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6905 Not a number, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
6908 First value received from IOServer, timestamp overwritten; values out of time sequence, intermediate point stored by deadband storage algorithm, partial cycle
7168 Bad Quality of undetermined state, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7169 No data available, tag did not exist at the time, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7170 Running insert, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7178 Communication loss, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7184 Good value, received out of time sync (cyclic tag), timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7185 Duplicate time stamp; infinite slope, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7188 IDAS overflow recovery, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7192 IOServer communication failed, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7212 Pipe reconnect, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7232 Cannot convert, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7318 Storage startup, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7319 Store forward storage startup, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7360 Good, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7370 Good point of version Latest, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7380 Counter rollover has occurred, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7416 First value received in store forward mode, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7417 Not a number, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
7420 First value received from IOServer, timestamp overwritten; server timestamping selected, intermediate point stored by deadband storage algorithm, partial cycle
65536 No data stored in history